Skip to main content

Table 1 Exposure predictions based on analysis of aerosols generated by smoking machines: volatile organic compounds

From: Peering through the mist: systematic review of what the chemistry of contaminants in electronic cigarettes tells us about health risks

Compound

N#

Estimated concentration in personal breathing zone

Ratio of most stringent TLV (%)

Reference

PPM

mg/m3

Calculated directly

Safety factor 10

Acetaldehyde

1

0.005

 

0.02

0.2

[5]

3

0.003

 

0.01

0.1

[4]

12

0.001

 

0.004

0.04

[8]

1

0.00004

 

0.0001

0.001

[3]

1

0.0002

 

0.001

0.008

[3]

150

0.001

 

0.004

0.04

[40, 41]

1

0.008

 

0.03

3

[38]

Acetone

1

0.002

 

0.0003

0.003

[38]

150

0.0004

 

0.0001

0.001

[40, 41]

Acrolein

12

0.001

 

1

13

[8]

150

0.002

 

2

20

[40, 41]

1

0.006

 

6

60

[38]

Butanal

150

0.0002

 

0.001

0.01

[40, 41]

Crotonaldehyde

150

 

0.0004

0.01

0.1

[40, 41]

Formaldehyde

1

0.002

 

0.6

6

[5]

3

0.008

 

3

30

[4]

12

0.006

 

2

20

[8]

1

<0.0003

 

<0.1

<1

[3]

1

0.0003

 

0.1

1

[3]

150

0.01

 

4

40

[40, 41]

1

0.009

 

3

30

[38]

Glyoxal

1

 

0.002

2

20

[38]

150

 

0.006

6

60

[40, 41]

o-Methylbenzaldehyde

12

 

0.001

0.05

0.5

[8]

p,m-Xylene

12

 

0.00003

0.001

0.01

[8]

Propanal

3

0.002

 

0.01

0.1

[4]

150

0.0006

 

0.002

0.02

[40, 41]

1

0.005

 

0.02

0.2

[38]

Toluene

12

0.0001

 

0.003

0.03

[8]

Valeraldehyde

150

 

0.0001

0.0001

0.001

[40, 41]

  1. #Average is presented when N > 1.